MACHINE ROOM AND HOISTING MACHINES
Geared Machine
Geared machines are specially designed and manufactured for the
Lift Industry. Consisting of a gearbox and motor, they are still widely used and have high lifting capacity from
200kg to 8000 kg and more.

Gearless Machine
Gearless machines are machines without a gearbox. The motor
becomes the machine this is usually used on high speed units and now for Machine-room-less lifts (M.R.L) as they
are compact and can easily fit into the shaft. The brake is spring applied and electrically released, resulting in
completely silent operation.

Main Drive Motor
The main drive motor is just a motor which is fixed onto the gear
box. In modernisations where the motor is DC a new VVVF motor will be fitted. This type of motor is more efficient
and cost effective to run.

Main Drive Motor Replacement
In this picture a new main drive motor is being fitted onto an existing Gearbox. We assess the
gearbox to make sure that it’s still in a good working condition.

Drive Motor Cooling Fan
This fan is used to cool the main motors.
Controller
A microprocessor based controller will be provided. (Unless specified differently
under our general specifications).

Microprocessor
Features
-
Completely CE certified panel by Lift institute “type
tested”.
-
VVVF Drive (Inverter) for a smoother ride and maximum motor
output.
-
4 lines, 20 characters LCD screen and 6 keys for easy
programming.
-
Last 128 errors can be analyzed with ease without any external device
needed.
-
Simplex, duplex, triplex and up to 8 lifts can work as a
group.
-
49 user programmable parameters for better functioning and without an
external device needed.
-
Real time clock for accurate fault finding.
-
Components are easily removable and readily available
locally.
-
Easy wiring connections for neater installation and faster fault
finding.
-
Durable controller box can be floor or wall
mounted.
Main Drive / Inverter
The inverter ensures a smooth operation as well as having acute
levels at all times, within 5mm under all load conditions.
A VVVF drive / inverter if provided
will ensure accurate levels within 5mm under all load conditions.
The drive / inverter calculates speed and torque based on the
following hardware information:
The Drive / Inverter also has a built-in dynamic braking system
that will prevent the elevator from over speeding when manually opening the mechanical brake (with or without
power). The safety feature helps with ensuring safe rescue conditions.
Trailing Cables
This extra flexible flat cable with 0.75 mm2 cross
section is suitable for connecting up elevators. The cables without steel core support can be used until 65 meter
free suspended length, the drift velocity doesn't exceed 4 m/s and the
environment's temperature is between -40o C and + 60o C.
24 conductor cable with steel core support can be used until 85
meter suspending length, maximum drift velocity 6m/sec. Cables with 1 mm2 cross section are used for longer
suspension length than 85 meter. This cable has been designed, manufactured and tested in accordance with EN 50214
standard.
By-Stables
Solenoids / by-stables work dead and react to a permanent magnet.
The special characteristics are characterised by large switching distances.
Rescue Device
Rescue device can be fitted onto the controller, in the event of a
power failure the lift will automatically level to the next floor opens the doors and shut
down.
Should emergency operation of the installation under emergency
power conditions be required and specific mention is made by us under the heading of “Special Features”, it is
agreed that we will provide the lift controllers with the necessary equipment and software to achieve the required
operation. The supply and installation of the emergency standby generator is however excluded from this quotation
unless otherwise specified herein.
Fire Control
In accordance with the National Building Regulations and SABS 0400
the lift equipment will be provided with a fire service feature, which will consist of a key type switch which when
activated will return the lifts to the designated fire lobby. Should automatic operation be required, a signal from
the fire detection systems in the building would need to be provided, but the detection system is excluded from
this quotation.
Ropes
Traction steel hoist ropes of size and number to ensure adequate
wearing and traction qualities.
The number of ropes supplied shall provide a factor of safety of
at least 12. Springs compensator's ropes hitch is to ensure even rope tension. Governor ropes are of steel and are
suitably dimensioned to ensure the safe and effective operation of the governor.
GOVERNOR AND SAFETY
Governor
The governor, once activated, will initially remove power from the driving motor and then
should a further speed increase be sensed, will apply the safety gear. The safety gear is released by raising
the car manually.

Safety Gear
The safety gear mechanisms are mounted beneath the bottom members
of the sling and are operated by a centrifugal governor.
CAR AND LANDING DOORS
Car Door Hanger
The car doors automatic and are suspended from a minimum of two neoprene shod steel
rollers per panel with sealed bearings. Fully adjustable steel up-thrust rollers are located opposite each concave
suspension roller. The roller assemblies run on a smooth steel track and individual door panels are connected via
air cord and sealed bearing sheaves.

Skid
The landing doors are coupled to the car doors via a clutch assembly, which unlocks the landing
doors as the car door commences opening.
Landing Doors
Landing doors are fully interlocked both mechanically and electrically ensuring the complete
mechanical locking of the landing door prior to car departure.

Doors Shoes
Door panels are individually adjustable in three dimensions on the hanger assemblies. Non-metallic shoes
running in the sill groove guide the doors at the foot of each panel.
Triangles Keys
Landing doors are supplied with a triangle-key device to facilitate opening under
abnormal conditions.

Swing Doors
Swing doors are made out of wood or steel. They are now generally used for home lifts.
Swing Door Landing Doors Door Lock
The lock is made out of cast-iron with copper contacts in the inside it is situated in the
inside of the landing door frame.

Lock Lever
The lock lever is made out of cast-iron with a brass rod which is attached to the lever.
The lock lever is attached to the swing door lock.
Door Closers
Door closers are used on swing doors to close the doors. They are situated on the top of
the door and work by a spring and hydraulics piston system inside.
Lock Contact / Bridge Contact
The bridge contact is fitted on the swing door it’s made out of moulded plastic with
copper end contacts. When the swing door closes this contact enters the landing door lock, connecting it
electrically and a lever in the lock will engage making the lock mechanically.
New Type Lock Assembly
This is the new type locks the can only be used when the landing and car doors are fully
automated.
Up Thrust Roller
This roller is fitted under the main roller on the hanger, this is to keep the doors from
coming off the hanger rails.
Hanger Rollers
This roller is fitted on top of the hanger and is to guide the door.
Lock Roller
The lock roller is made out of rubber or plastic with a brass bush or steel bearings which
is attached to the lock lever. The lock lever is attached to landing door lock.
Gate Switch
The gate switch is fitted on the car door hanger, this switch is the safety switch for the car
doors, should the car doors open, a contact inside will open causing the lift top stop.
Door Protection
Door detectors are infrared beams which cover the entrance of the Car doors, when the
beams are interrupted by a person or object the lift doors will then reopen or remain open until the obstruction is
removed. This eliminates the use of the old safety shoes, which was mechanical and had to make contact (hit) the
person or object to open the doors thus causing the doors to go out of adjustment and the lift stopping.

Door Motor & Door Drive Inverter
Old door drives are replaced with new AC door motors and VVVF drives / inverters with 6 speed
settings to ensure a smooth open and close function and ensuring a reliable and rugged system.

General Note
Users will not be able to open the landing doors under power failure conditions or when
the elevator malfunctions. Only trained personnel with be able to open the car doors under the described
conditions.
LIFT CAR
Car Interiors
SEE CABIN INTERIORS
Car Operating Panels (C.O.P)
The car-operating panel is situated on a sidewall and is incorporated into the car design. The
unit will consist of call registration devices, auxiliary switches and buttons which is required for the correct
operation of the elevators.(Unless specified differently under our general specifications)
A digital car position indicator is conveniently located on the car operating panel
together with the emergency unit i.e. intercom. As well a key switch which can be used to switch off lights or the
lift.

Emergency Lighting And Alarm
A concealed standby battery and trickle charger will be provided to ensure proper functioning of
the emergency light and alarm in the event of a power failure.

TOP OF CAR
Car Guide Rollers
The rollers are situated on top and under the car on the sling and crossbar. They are
manufactured from cast-iron and steel with a spring system to dampen any vibrations.
Car Guide Shoes
The guide shoes are situated on top and under the car on the sling and crossbar. They are
manufactured from cast-iron and steel with nylon or polyurethane inserts and are lubricated with oil pots which are
fitted on top of them.

Inspection Unit
This control device is situated on top of the car and is used by our technicians to control the
lift while servicing.
Limit Switches
These fitted in the shaft at the top and bottom for the final slow down as well as for when
the lift overruns top floor or bottom floor they act as a safety switches to stop the lift from hitting any
concrete.
LANDING SIGNALS AND CONTROLS
Landing Buttons
At each landing, self illuminating push buttons work as follows. Full collective control
systems have two buttons in a common face plate at intermediate landings with a single button at terminal landings.
Unidirectional controllers have a single button at each landing.

Positions Indicators (Digital)
At the ground or main floor (unless specified differently under our general specifications) a
digital position indicator is located in the frame header above the entrance. The indicator consists of numerical
digital indications in a stainless steel face plate.

Rope Gripper
Rope Grippers are used only on certain machines or when called for by an inspector. They operate
in conjunction with a special governor by clamping the main ropes should the lift over speed in any direction.

Guides
The guides for car and counterweights are planed or cold rolled steel. These are erected
plumb and securely fastened to the shaft. The method of attaching guides at each bracket allows for considerable
expansion and contraction without any guide distortion.
The ends of each guide length are tongue and grooved and connected to steel fish-plates to
ensure accurate alignment.
Counterweight
The lift car is carefully counter balanced in order to achieve a smooth and economical
operation. The counterweight shall equal the mass of the complete car plus approximately 45% of the maximum
load.
The counterweight assembly consists of a structural steel frame in which cast iron filler
weights are secured.
Counterweight filler blocks are painted yellow to comply with local regulations. Four
guide shoe assemblies guide the frame on its guide rails.

BUFFERS AND PIT
Buffers
Buffers are mounted in the pit beneath the car and counter weight assemblies. The buffers are
designed to arrest either car or counterweight at full contract speed.

Emergency Stop Switch
Fitted in the pit this is a push and pull switch.

|