Escalators and Passenger
Conveyors




 |
Please click on this image to
view shaft layout drawings, load capacity's and printable image.
|
O Degree
Conveyer |
 |
Please click on this image
to view shaft layout drawings, load capacity's and printable image.
|
1O-11-12
Degree Conveyer |
 |
Please click on this image to
view shaft layout drawings, load capacity's and printable image.
|
30 Degree
Escalator |
 |
Please click on this image to
view shaft layout drawings, load capacity's and printable image.
|
35 Degree
Escalator |





| Traffic control and different types of handrail colours |
Safety Features
Handrail Entry Guard
This device is fitted at the entry of the handrail to prevent any injuries caused due to any objects,
especially children's fingers being pulled into the handrail gaps. The contacts of this device break under the
action of thrust and will disconnect the power bringing the escalator to a standstill.
Emergency Stop
Button
Emergency stop button is provided at the entry and exit to the handrails of the
escalator. Its function is to disconnect the power shutdown the escalator in case of any
emergencies.
Broken Step Chain Safety
Device
Although the strength of the step chains are fully tested
we still taken into account that a device can still malfunction, therefore should a chain unexpectedly break or
stretch, the escalator will immediately come to a standstill.
Comb Plate Safety
Device
The
contacts of
the comb plate are
located on the back of
the
comb plate. If there are any foreign
objects jammed
in it, the comb plate will move horizontally and vertically, when this happens, the power will be disconnected
and the escalator will come to a standstill and shut down.
Step Sagging
Detector
Breaking of the escalator steps is very dangerous. So
lower limit contacts for the steps are provided in the truss. When a step sags by 3mm, the contacts will make
and immediately trip bringing the escalator to a standstill.
Abnormal Step
Detector
If any step is lose or not in line, the escalator will
stop immediately after trying to run.
Power Protection
Device
Phase monitor is installed to prevent reverse phasing.
The escalator can still operate normally when the voltage or frequency
fluctuates.
Over Speed Protection
Device
The escalator will stop immediately if running speed is
over or below its rated speed.
Electromagnetic Brake
It will stop the operation of the escalator quickly and
with a steady slow down in case of any motor faults.
Protection device for unintentional reversal of
the travel direction
This function is to prevent the escalator running in the
different direction from its current travel direction.
Broken Drive-chain Safety
Device
This function is to disconnect the power stop the escalator in
case the drive chain break or stretch.

|